Buy SPL Lab measurement microphones & SPL measuring devices cheaply online at Masori
Discover the comprehensive selection of SPL Lab measurement microphones and SPL measuring devices at Masori, your Carhifi online shop. Our high-quality sound level meters from SPL Lab provide precise acoustic measurements for professional applications. With advanced sensors and robust design, these devices are ideal for acoustic studies, noise analyses, and technical audit tests. Benefit from detailed technical specifications and versatile applications that make SPL Lab products optimal tools for audio professionals.
Overview of SPL Lab Measurement Microphones
SPL Lab measurement microphones are specifically designed to ensure accurate sound measurements in various environments. With high sensitivity and a wide frequency response, these microphones enable precise recordings of noise levels. The compact design and robust housing ensure reliable performance even under demanding conditions. Ideal for applications in acoustic research, vehicle noise monitoring, and workplace assessment, these measurement microphones provide consistent and repeatable results.
Technical Specifications of the SPL Measuring Devices
SPL measuring devices from SPL Lab are characterized by their high accuracy and user-friendliness. Typical models have a measurement range coverage of 30 to 130 dB, with an accuracy of ±1.5 dB. The devices are equipped with digital displays that allow real-time measurements, as well as various filter options such as A-, C-, and Z-weightings to adapt to specific measurement requirements. Thanks to the integrated memory function, measurement data can be easily stored and analyzed.
Applications of voltmeters in SPL Lab products
The voltmeter in the SPL Lab products serves for precise voltage measurement, which is essential for the calibration and monitoring of the measuring devices. It allows for accurate control of the operating voltage and ensures that the measuring devices operate within optimal performance parameters. This function is particularly important in laboratory settings, where precise electrical measurements are necessary for the validation of acoustic data. The integration of the voltmeter ensures reliable and stable performance of the SPL Lab devices.
Installation and use of SPL Lab measuring devices
The installation of the SPL Lab measuring devices is straightforward thanks to the thoughtful design. With clear connection options and intuitive controls, the devices can be quickly and efficiently integrated into existing systems. For optimal placement of the measurement microphones, it is advisable to follow the manufacturer's instructions to ensure accurate measurements. If needed, Masori offers an on-site installation service in Frankfurt Oder, ensuring professional installation and setup of the devices. You can find expert support FAQ & Help here.
Accessories for SPL Lab Measuring Instruments
To expand the functionality of the SPL Lab measuring devices, Masori offers a variety of suitable accessories. These include calibration adapters, external storage solutions, and special mounts for precise positioning of the measurement microphones. Additionally, protective housings and transport cases are available to ensure the safe transport and storage of the devices. Furthermore, we provide accessories for the integration of the measuring devices into various measurement systems to enable seamless use in different application areas.
Performance data and impedance of the SPL Lab products
The SPL Lab products feature detailed performance data that allow for precise adaptation to specific measurement requirements. Typically, the impedance values of the measurement microphones are 200 ohms, ensuring optimal compatibility with most amplifiers and recording devices. The high signal-to-noise ratio of over 60 dB guarantees clear and unaltered measurement signals. These characteristics make the SPL Lab devices reliable tools for acoustic analyses in professional applications.
Different construction methods: Measurement microphones vs SPL measuring devices
SPL Lab offers both measurement microphones and SPL measuring devices, which differ in their design and application. Measurement microphones are specifically designed to capture sound waves and feature sensitive diaphragms for precise sound capture. SPL measuring devices, on the other hand, integrate these microphones into a complete measuring system that processes and displays the captured data. This combination enables comprehensive acoustic analyses and real-time measurements that can be used in various industrial and laboratory applications.
Tips for Setting Up SPL Lab Devices
For optimal use of the SPL Lab devices, careful setup is required. Start with the calibration of the measurement microphones according to the manufacturer's instructions to ensure accurate measurements. Position the microphones at strategic locations to achieve comprehensive coverage of the area to be measured. Activate various filter options depending on application needs and regularly check the acoustics of the environment to identify and minimize potential sources of interference. More helpful tips and guides can be found in our audio blog here.
Variants and selection of SPL Lab products
The SPL Lab product range includes a variety of measurement microphones and SPL measuring devices designed for different applications and requirements. From compact handheld devices for mobile measurements to stationary systems for comprehensive laboratory measurements, SPL Lab offers flexible solutions. The selection includes devices with varying measurement ranges, accuracies, and additional features such as Bluetooth connectivity and expanded storage options. This way, every specific requirement can be met with the appropriate device.
Support and Service for SPL Lab Customers
Masori places great importance on excellent customer service for users of SPL Lab products. In addition to offering a professional installation service in Frankfurt Oder, our expert support FAQ & Help is available to you at any time. If you have technical questions or issues with the use of your devices, you can rely on our competent support. Furthermore, the Audio Blog provides valuable tips and information for the optimal use and maintenance of your SPL Lab measuring devices. You can find more information under FAQ & Help and in the Audio Blog.
FAQ - frequently asked questions
How do I calibrate my SPL meter from SPL Lab?
To correctly calibrate your SPL meter from SPL Lab, start by preparing the calibration accessories included in the package. Connect the meter to a stable power source and place the measurement microphone within range of a known sound source. Follow the detailed steps in the user manual to make the calibration settings. Then check the measurement accuracy by comparing real sound levels with the displayed values. Regular calibrations are essential to ensure precise measurement results in the long term.
What filter options do the SPL Lab measurement microphones offer?
SPL Lab measurement microphones are equipped with various filter options, including A, C, and Z weightings. The A-weighting is ideal for general sound level measurements as it best reflects human hearing perception. The C-weighting is often used for industrial applications as it also takes into account lower frequencies. The Z-weighting provides an unchanged frequency response, which is necessary for precise technical analyses. This flexibility allows the measurement microphones to be adapted to specific requirements and to achieve accurate results in different scenarios.
What technical specifications are particularly important for SPL measuring devices?
In SPL measuring devices from SPL Lab, the measurement range coverage, accuracy, and signal-to-noise ratio are particularly crucial technical specifications. A typical measurement range of 30 to 130 dB allows for the capture of both quiet and very loud sounds. An accuracy of ±1.5 dB ensures that the measurements are reliable and consistent. A high signal-to-noise ratio of over 60 dB minimizes unwanted background noise and provides clear and precise measurement results. Other relevant technical specifications include the impedance of the measurement microphones and the connection options of the devices.
How do I choose the right measurement microphone for my application?
The selection of the right measurement microphone from SPL Lab depends on several factors, including the type of application, the required frequency response, and the environmental conditions. For precise acoustic studies, microphones with high sensitivity and a wide frequency range are ideal. In industrial environments, where robust construction and noise reduction are important, microphones with reinforced housings and special filter options should be considered. Additionally, it is important to match the impedance of the microphones to the existing amplifiers and recording devices to ensure optimal performance.
What accessories are recommended for the use of SPL Lab measuring devices?
For optimal use of the SPL Lab measuring devices, it is advisable to acquire suitable accessories such as calibration adapters, external storage solutions, and special mounts. Calibration adapters are necessary to precisely calibrate the devices and ensure accurate measurement values. External storage solutions allow for the storage of extensive measurement data for later analysis. Special mounts ensure stable and precise positioning of the measurement microphones, which is particularly advantageous in dynamic environments. Furthermore, transport cases can facilitate the safe transport and storage of the devices.
How does the voltage measurement work in the SPL Lab voltmeter?
The voltmeter in the SPL Lab products measures the operating voltage of the measuring devices precisely to ensure their proper functioning. It continuously monitors the voltage and provides real-time data that can be used to adjust and optimize the device performance. Accurate voltage measurement is essential to detect fluctuations and take appropriate countermeasures, thereby ensuring the stability and accuracy of the measurements. By integrating the voltmeter into the overall system, users can quickly respond to voltage changes and maximize the performance of their SPL Lab devices.
What differences are there between A-, C-, and Z-weightings?
A-, C-, and Z-weightings are different filter options integrated into SPL Lab measurement microphones to enable various sound level measurements. The A-weighting is the most commonly used option and adapts to human hearing perception by attenuating lower and higher frequencies. It is excellent for general sound level measurements in offices and living spaces. The C-weighting, on the other hand, captures more low frequencies and is therefore ideal for industrial environments where low-frequency noises dominate. The Z-weighting provides an unfiltered measurement and is used when a precise technical analysis of the entire frequency bandwidth is required.
How can I optimize the performance of my SPL Lab measuring devices?
To optimize the performance of your SPL Lab measuring devices, it is important to carry out regular calibrations and ensure that the measurement microphones are correctly positioned. A clean power supply and the use of high-quality accessories such as calibration adapters also contribute to the accuracy of the measurements. Additionally, the environment should be carefully prepared by minimizing disruptive noises and ensuring a stable mounting of the devices. By combining these measures, you can maximize the precision and reliability of your SPL Lab measuring devices and achieve consistent results.
What advantages does the installation service from Masori offer for SPL Lab products?
The installation service from Masori for SPL Lab products offers numerous advantages, including professional installation by experienced technicians who ensure optimal placement and setup of the devices. The service includes customizing the measuring instruments to specific customer requirements and integrating them into existing systems, allowing for immediate and efficient use. Additionally, it ensures that all devices are correctly calibrated and ready for operation, which increases the accuracy and reliability of the measurements. With the installation service, you can ensure that your SPL Lab products function optimally from the start and that your acoustic measurements are precise and reliable.