66160H - 40Ah LTO A-Grade
66160H - 40Ah LTO A-Grade
Technical Highlights
- Nominal voltage 2.3V, capacity 40Ah, max. discharge current 400A.
- Optimal charging current 40A, discharge cut-off voltage 1.8-2.0V.
- Operating temperature -55°C to 65°C, weight approx. 1.25 kg.
- More technical details
Availability for pickups could not be loaded.
Shipping cost calculator
Pay in instalments
This product is not universally compatible. Send us your vehicle details and we will check fitment for your model free of charge.
66160H - 40Ah LTO A-Grade is a Lithium - LTO cylindrical cell from Yinlong. The cell has a capacity of 40 Ah at a nominal voltage of 2.3 V. Dimensions are 66 x 66 x 160 mm, with a thread length of 202 mm, and a weight of approximately 1.25 kg. Maximum charge and discharge current is 400 A each, optimal at 40 A. Operating temperature range is -55°C to 65°C. Charge cutoff voltage is 2.5–2.65 V (manufacturer's specification 2.8 V) and discharge cutoff voltage is 1.8–2.0 V (manufacturer's specification 1.5 V). Revised contact surfaces for low contact resistance. Tested with at least 40 Ah and AC internal resistance <0.5 mΩ. Optimal operating range is 2.0–2.5 V.
- Lithium - LTO cylindrical cell
- Manufacturer: Yinlong
- Model: 66160H
- Capacity 40 Ah
- Nominal voltage 2.3 V
- A-Grade (new)
- Revised contact surfaces for low contact resistance
- AC internal resistance <0.5 mΩ (guaranteed)
- At least 40 Ah capacity (tested)
- Weight approximately 1.25 kg
- Height 160 mm (202 mm with thread)
- Width 66 mm
- Depth 66 mm
- Max. charge current 400 A
- Optimal charge current 40 A
- Max. discharge current 400 A
- Optimal discharge current 40 A
- Operating temperature -55°C to 65°C
- Charge cutoff voltage 2.5–2.65 V (manufacturer's specification 2.8 V)
- Discharge cutoff voltage 1.8–2.0 V (manufacturer's specification 1.5 V)
- Optimal operating range 2.0–2.5 V
- Maintenance charging: not recommended; adjustable to 2.25 V per cell with solar charge controllers
- Voltage behavior: above 2.5 V, the voltage increases more sharply, above 2.6 V very sharply; below 2.0 V similarly
- Note for very high currents: operating range may need to be further restricted to avoid strong voltage spikes or drops
- Active balancer is important for cells connected in series
- System notes: 12 V system – 6 cells; 24 V system – 11 cells; 48 V system – 22 cells